Configuration MC13xx Users Manual Rev. 1.08
6.8.7 Asynchronous exposure, shutter control by timer
This operating mode is selected with register 6:
:r6[7..4] = 0xf
The asynchronous exposure time is dependent on :r2[9..0]. The exposure timer counts as many lines as
are defined in register :r2[9..0].
Exposure time:
T
B
= 1/F
sens
* 136 (1+r2[9..0]) [Sec]
T
B
... exposure time
F
sens
.. sensor clock
example: sensor clock = 66MHz
value of r2[9..0] = 6
T
B
= 136 6
15 ns = 12,2 µs